Filter by :
Procedures
Product Portfolio
Sort by :
Used to gain access to desired anatomical location and to assist in placement of medical devices during diagnostic or interventional procedures.
Transparent Tip
Platinum Ring
Tapered Dilator
Hydrophilic Coated
Used to gain smooth and easy access to desired anatomical location and to assist in placement of medical devices.
Hydrophilic coating provides easy passage in tortuous anatomy and through lesions
Radiopaque polymer jacket enhances fluoroscopic visualization
Kink resistant nitinol core for optimal performance
Used to gain access to desired anatomical location and to assist in placement of medical devices.
Is constructed with kink resistant Nitinol core with appropriate stiffness for deployment of devices
Atraumatic floppy tip facilitates easy insertion and access
Blue and White sleeve provides excellent visualization and easy maneuvering
Used to gain access to desired anatomical location and to assist in placement of medical devices
during diagnostic or interventional procedures.
PTFE Coating for smooth insertion
Atraumatic floppy tip for less trauma
Uniform outer diameter
Used for fine aspiration for Cytological study.
The special echogenic tip increases the visibility under ultra sound guidance and ensures the needle point’s localization.
Intended to be implanted for drainage of urine from renal pelvis to urinary bladder.
Thermosensitive, advanced PU material for enhanced patient comfort
Stent will be stiffer at room temperature promoting pushability for stent deployment
Material becomes softer at body temperature
Optimal loop shape and high memory retention reduces the risk of migration
Optimal radiopacity for better visualization
Intended for percutaneous dilation of tissue surrounding a dilator previously placed. It is used as a working channel to maintain a previously established nephrostomy tract for introduction of instruments and catheters during urological procedures.
Optimal Bevel tip for atraumatic entry
Smooth surface for ease of introduction
Optimal radiopacity for better visualization
Used to remove the stones and retrieval of foreign objects under direct vision.
Used for stenting the urethra after Hypospedias or Epispedias repair and to provide post-operative
drainage of the bladder.
Smooth surface for ease of introduction
Radiopaque for better visualization
Hydrophilic coating for easy insertion
Used for self-dilation of Urethral strictures.
Tapered end for atraumatic entry during dilation
Smooth surface for ease of introduction
Used for one step dilation of the ureter through natural orifice prior to a diagnostic or interventional procedure.
Long tapered tip avoids use of sequential dilation
Smooth surface for atraumatic entry during dilation
Also available with hydrophilic coating for ease of introduction
Optimal radiopacity for better visualization
Used for coagulation during the TURP Procedure.
Manufactured compatible to resectoscopes of Karl Storz, Wolf, Olympus & ACMI
Intended for stretching or enlarging the fascial tissue prior to a nephrostomy procedure and to
introduce the amplatz sheath which is intended for percutaneous dilation of tissue surrounding a dilator previously placed and used as a working channel during urological procedures.
Used to be inserted percutaneously into the renal pelvis upto the ureter to perform external drainage of urine from the renal pelvis and internal drainage into the bladder.
The Malecot flower design is ideally suitable for the drainage of thick viscous fluids
Integral flower design matches with the catheter size when closed and cause less trauma during insertion
Used as a nephrostomy catheter and also as ureteral stent
Used for percutaneous placement of a pigtail catheter in the renal pelvis for nephrostomy drainage.
Used for percutaneous placement of a Malecot Catheter in the renal pelvis for nephrostomy drainage.
Used for percutaneous placement of a pigtail catheter in the renal pelvis for nephrostomy drainage by direct puncture.
The pigtail tip configuration helps in the retention of the distal tip in the renal pelvis
Eye holes for better drainage
Trocar design and catheter design prevents buckling of catheter during the procedure
Also available in Hydrophilic coating for easy insertion
PCN catheter is intended to be inserted percutaneously into the renal pelvis to perform external drainage of urine. The locking mechanism prevents accidental slippage of the catheter.
The pigtail tip configuration helps in the retention of the distal tip in renal pelvis
The locking mechanism prevents accidental slippage of the catheter
Eye holes for better drainage
Also available with Hydrophilic coating for easy insertion
Intended to be implanted for drainage of urine from renal pelvis to urinary bladder.
For indwelling up to 30 days
Polyurethane based stent has uniform diameter and smooth surface reducing encrustation
Optimal loop shape and high memory retention reduces the risk of migration
Optimal radiopacity for better visualization
Used for obtaining histological core samples from soft tissue and organs.
Echogenic and atraumatic needle tip
Ergonomic and light weight
Cannula with depth marking
Easy and one hand operated with two stage arming
Used for dilation of percutaneous tract for nephrostomy procedure.
Controlled inflation pressure allows dilating force at a nephrostomy tract
Radiopaque marker bands enhance visualization of balloon position under fluoroscopy
Stone Basket is intended to be used in an endoscopic procedure for removal of urinary stones or foreign objects from the Ureter or the Kidney.
Zero tip design reduces chances of perforation and mucosal damage, which also avoids stone migration during the procedure
Nitinol wire construction with high strength and high memory helps the basket to retain its shape during extreme torsion
In case of stone impregnation in the basket during the procedure, ergonomic handle permits full disassembly
Flexible Stone Basket is intended to be used in an endoscopic procedure for removal of urinary stones or foreign objects from calyx.
Flexible design shaft which can angulate up to 270 degrees as per the flexible scope direction during RIRS Procedure
Kink resistant braided shaft provides durability, making removal of several fragments possible
Tipless design helps in easy capturing of stones by allowing the basket to open at the base of calyx and encircle the stone
Nitinol wire construction with high strength and high memory helps the basket to retain its shape during extreme torsion
Used for self-dilation of penile urethral meatus.
Designed specifically for dilation of meatal strictures
Atraumatic design
Uniform taper and smooth surface for easy insertion
Superior handling grip
Malecot catheter is intended to be inserted percutaneously into the renal pelvis to perform external drainage of urine.
The Malecot flower design is ideally suitable for the drainage of thick viscous fluids
Integral flower design matches with the catheter size when closed and cause less trauma during insertion
Together, we achieve extraordinary outcomes.